:: DiSEqC 1.0: all 16 switch options
Switch
option
Polarisation
Frequency band
LNB
Command
"Position"
Command
"Option"
Command
"Tone Burst"
1
V (13 V)
Low (0 kHz)
A
0
0
0
2
V (13 V)
High (22 kHz)
A
0
0
0
3
H (18 V)
Low (0 kHz)
A
0
0
0
4
H (18 V)
High (22 kHz)
A
0
0
0
5
V (13 V)
Low (0 kHz)
B
1
0
1
6
V (13 V)
High (22 kHz)
B
1
0
1
7
H (18 V)
Low (0 kHz)
B
1
0
1
8
H (18 V)
High (22 kHz)
B
1
0
1
9
V (13 V)
Low (0 kHz)
C
0
1
0
10
V (13 V)
High (22 kHz)
C
0
1
0
11
H (18 V)
Low (0 kHz)
C
0
1
0
12
H (18 V)
High (22 kHz)
C
0
1
0
13
V (13 V)
Low (0 kHz)
D
1
1
1
14
V (13 V)
High (22 kHz)
D
1
1
1
15
H (18 V)
Low (0 kHz)
D
1
1
1
16
H (18 V)
High (22 kHz)
D
1
1
1